Maintenance; Motor Specifications And Part No - Chore-Time Turbo Installation & Operator's Instruction Manual

36” direct drive fiberglass cone fan and grill fan
Table of Contents

Advertisement

TM
TURBO
Fiberglass Cone and Grill Fan—36" Direct Drive
Service and maintenance of fans should be done only by a qualified technician.
Disconnect Power prior to maintaining or cleaning the fan! The fan may start
automatically causing injury or death.
1. Keep the fan clean for maximum life and best performance.
2. Clean Shutter, Cone and Shroud for maximum life and performance.
3. The Fiberglass Fans are shipped with the Danger Decal fastened to the Fan
Shroud. Always keep the Decal clean and readable.
If the Decals becomes damaged or unreadable, order replacement Decals immediately.
Clean the Shroud at the approximate location where the Decal will be placed.
Peel the backing off the Decal and affix it to the Shroud.
*
Important!
Chore-Time Equipment strongly recommends that a good alarm system should be installed
in confinement buildings to warn of power failure and high temperature.
Chore-time Equipment also recommends that an alternate power source be available for
confinement buildings in case of power failure.
12

Maintenance

Motor Specifications and Part No.

Fan
Specifications
(assembled)
*
Description
Part No.
38265-362X
38265-364X
Fiberglass
Cone
38947-362X
38947-364X
Grill
Replace the "X" in fan P/N with "1" for an aluminum Shutter, "2" for a plastic shutter.
Motor Specifications
Voltage
HZ
Phase
208/230
60
1
208/230-460
60
3
208/230
60
1
208/230-460
60
3
HP
Motor
P/N
.5
37737
.5
38911
.5
37337
.5
38911