Module Diagnostic Items - Allen-Bradley PowerFlex 20-COMM-D User Manual

Devicenet adapter
Table of Contents

Advertisement

Module Diagnostic Items

The following diagnostic items can be accessed using DriveExplorer
(version 2.01 or higher).
No. Name
1
Common Logic
Cmd
2
Prod Logic Cmd Current value of the Product Specific Logic Command being transmitted to
3
Reference
4
Common Logic
Sts
5
Prod Logic Sts
6
Feedback
7
Datalink A1 In
8
Datalink A2 In
9
Datalink B1 In
10
Datalink B2 In
11
Datalink C1 In
12
Datalink C2 In
13
Datalink D1 In
14
Datalink D2 In
15
Datalink A1 Out Current value of Datalink A1 being received from the host by this peripheral.
16
Datalink A2 Out Current value of Datalink A2 being received from the host by this peripheral.
17
Datalink B1 Out Current value of Datalink B1 being received from the host by this peripheral.
18
Datalink B2 Out Current value of Datalink B2 being received from the host by this peripheral.
19
Datalink C1 Out Current value of Datalink C1 being received from the host by this peripheral.
20
Datalink C2 Out Current value of Datalink C2 being received from the host by this peripheral.
21
Datalink D1 Out Current value of Datalink D1 being received from the host by this peripheral.
22
Datalink D2 Out Current value of Datalink D2 being received from the host by this peripheral.
23
Field Flash Cnt Current value of the Field Flash Counter.
24
DPI Rx Errors
25
DPI Tx Errors
26
DN Rx Errors
27
DN Tx Errors
Description
Current value of the Common Logic Command being transmitted to the host
by this peripheral.
the host by this peripheral.
Current value of the Product Specific Reference being transmitted to the host
by this peripheral.
Current value of the Common Logic Status being received from the host by
this peripheral.
Current value of the Product Specific Logic Status being received from the
host by this peripheral.
Current value of the Product Specific Feedback being received from the host
by this peripheral.
Current value of Datalink A1 In being transmitted to the host by this peripheral
(if not using Datalink A1, this parameter should have a value of zero).
Current value of Datalink A2 In being transmitted to the host by this peripheral
(if not using Datalink A2, this parameter should have a value of zero).
Current value of Datalink B1 In being transmitted to the host by this peripheral
(if not using Datalink B1, this parameter should have a value of zero).
Current value of Datalink B2 In being transmitted to the host by this peripheral
(if not using Datalink B2, this parameter should have a value of zero).
Current value of Datalink C1 In being transmitted to the host by this peripheral
(if not using Datalink C1, this parameter should have a value of zero).
Current value of Datalink C2 In being transmitted to the host by this peripheral
(if not using Datalink C2, this parameter should have a value of zero).
Current value of Datalink D1 In being transmitted to the host by this peripheral
(if not using Datalink D1, this parameter should have a value of zero).
Current value of Datalink D2 In being transmitted to the host by this peripheral
(if not using Datalink D2, this parameter should have a value of zero).
Current value of the DPI CAN Transmit Error Counter register.
Maximum value of the DPI CAN Transmit Error Counter register.
Current value of the DNet CAN Receive Error Counter register.
Maximum value of the DNet CAN Receive Error Counter register.
Troubleshooting
7-5

Advertisement

Table of Contents
loading

Table of Contents