ALLIANCE BA120E Installation Manual page 54

Tumble dryers
Table of Contents

Advertisement

Electrical Requirements
120 Series Electric Models
Code
Voltage
G
230-240
H
380
J
400-415
K
440
L
460-480
170 Series Gas and Steam Models
Code
Voltage
Q
200-240
N
440-480
P
380-415
200 Series Gas and Steam Models
Code
Voltage
Q
200-240
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Cycle
Phase
50-60
3
50-60
3
50-60
3
50-60
3
50-60
3
Table 8
Cycle
Phase
50-60
3
50-60
3
50-60
3
Table 9
Cycle
Phase
50-60
3
Table 10  continues...
Terminal
Full Load
Block Con-
Amps
nections Re-
quired
L1, L2, L3
147
and ground
L1, L2, L3
94
and ground
L1, L2, L3
86
and ground
L1, L2, L3
82
and ground
L1, L2, L3
75
and ground
Terminal
Full Load
Block Con-
Amps
nections Re-
quired
L1, L2, L3
11
and ground
L1, L2, L3
6
and ground
L1, L2, L3
7
and ground
Terminal
Full Load
Block Con-
Amps
nections Re-
quired
L1, L2, L3
12
and ground
54
Recommend-
Wire Size
ed Circuit
AWG [mm2]
Breaker Rat-
ing Amps
200
3/0 [95]
125
1 [50]
110
2 [35]
110
2 [35]
100
3 [26.7]
Recommend-
Wire Size
ed Circuit
AWG [mm2]
Breaker Rat-
ing Amps
15
14 [2.5]
15
14 [2.5]
15
14 [2.5]
Recommend-
Wire Size
ed Circuit
AWG [mm2]
Breaker Rat-
ing Amps
15
14 [2.5]
Part No. 70532501ENR7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga120eHa120nHu120lPk120nNk120nSj120e ... Show all

Table of Contents