Making Electrical Connections - Paramount Fitness Clear 03 Installation Manual

For ozone pure water. water purifying system
Hide thumbs Also See for Clear 03:
Table of Contents

Advertisement

MAKING ELECTRICAL CONNECTIONS

1. A licensed electrician should make all electrical connections. Make
sure the unit is grounded by connecting to the pool equipments bond
wire to comply with local electrical codes. See wiring diagram ( Fig. 4 ).
2. Turn off power to the filtration system pump at the circuit breaker.
3. Install an approved seal tight flex conduit (not included) rated for
outdoor use between the Clear O3
time clock with the wires running inside ( Fig. 5A & 5B ). Electrical
connections should be facing downward.
Fig. 4:
BLACK
GREEN
SIDE OF BALLAST
For technical assistance call 1.800.621.5886 or contact your regional representative
WARNING:
Turn off power at main source before making any
electrical connections or servicing the unit.
WHITE
OUTPUT
30-60 Vac 700mA - 800mA
CLASS P, TYPE 1, RATING: A
"RS" ELECTRONIC BALLAST
®
unit and filtration system pump
120 Vac 50-60 Hz 0.8A
BLACK
PWR
GREEN
GND
WHITE
NEG
WIRE NUTS
WHITE
BLACK
LAMP
7
230 Vac 50-60 Hz 0.38A
BLACK
GREEN
WHITE
INPUTS
2X RED
2X BLUE
PWR LINE 1
GND
PWR LINE 2
BLACK
GREEN
WHITE

Advertisement

Table of Contents
loading

Table of Contents