EXTERNAL SAFETY AIR BLEED KIT INSTRUCTIONS
Sometimes the internal
air bleed on the filter is
not sufficient to handle
the extra air in the system
with an ozonator installed.
An External Safety Air
Bleed Kit (006-402-
3872-00) ( Fig. 23 ) for
in-ground swimming
pools is available to
remove excess air from
the filter and send it
downstream (up to 15')
past all equipment. After installing always test per instructions that air is
vented from the filter when the pump is running. You must install an
external air bleed if the filter is old, does not have an internal air bleed,
there is a solar system on the pool or there is a robotic pressure side
cleaner.
Mounting Instructions
1. Turn the power off to
the pump.
2. Remove the pressure
gauge from the filter.
3. Install the nipple into one
end of the brass tee.
4. Install the pressure
gauge by threading into
the other end of the
brass tee supplied.
5. Install the tubing
compression fitting by threading into the side of the brass tee.
For technical assistance call 1.800.621.5886 or contact your regional representative
(OPTIONAL)
Fig. 23
External Safety Air Bleed Kit
Fig. 24
1
Filter
From
Pump
Installation of External Safety Air Bleed Kit
17
2
3
Heater
Chlorinator
Biostat/
Biocide
4
Return Line