Paramount Fitness Ultra UV2 Instruction & Operation Manual

Paramount Fitness Ultra UV2 Instruction & Operation Manual

Ultimate uv water sanitizer
Hide thumbs Also See for Ultra UV2:

Advertisement

IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
• Turn off power at main source before making any electrical connections or servicing the unit.
• To reduce the risk of electric shock, injury or death disconnect unit from power supply
• Follow the instructions or risk of serious injury or death could occur!
• To reduce risk of injury, do not permit children to use this product unless they are closely
supervised at all times.
• Risk of electric shock. Install at least 5 feet (1.5m) from inside wall of pool, hot tub or spa using
nonmetallic plumbing.
• This product shall only be connected to a power supply receptacle protected by a ground fault
circuit interrupter.
UV EXPOSURE & PROTECTION:
UV-A and UV-B radiation can have adverse short and long term effects on the eyes and skin. Never
look directly at a UV lamp that is connected to a power source. Avoid UV skin exposure at all times.
DANGER
SAVE THESE INSTRUCTIONS
295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
Paramount@1Paramount.com • www.1Paramount.com
004-027-9000-00
RISK OF INJURY
A) Replace damaged cord immediately.
B) Do not bury cord
C) Connect to a grounded, grounding type receptacle only.
Pool, Spa & Pond
Water Sanitizer 4BJ1
REV 01
Publish 07/17/18
INSTALLATION &
OPERATIONS MANUAL
When using this electrical equipment, basic safety precautions
should always be followed, including the following:
• Follow all applicable electrical codes.
EPA Registered
#084221-AZ-001
ECN_1584

Advertisement

Table of Contents
loading

Summary of Contents for Paramount Fitness Ultra UV2

  • Page 1 INSTALLATION & OPERATIONS MANUAL IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS When using this electrical equipment, basic safety precautions WARNING should always be followed, including the following: • Follow all applicable electrical codes. • Turn off power at main source before making any electrical connections or servicing the unit. •...
  • Page 2: Table Of Contents

    TROUBLESHOOTING ..............................13 ULTRA UV2 PART NUMBERS ..........................16 WELCOME The Ultra UV2 unit is designed for use in swimming pools, spas, fountains, water features, waterfalls, fish ponds and the like. It is not designed for use in potable (drinking) water installations.
  • Page 3: Ultra Uv2 System Sizing

    ULTRA UV2 SYSTEM SIZING In order to ensure that your Ultra UV2 unit functions with the proper water exposure time to achieve the desired water sanitation, it is important to provide the proper water flow rate through the Ultra UV2 unit. If water passes through the unit too quickly, the microorganism’s exposure time to the UV lamp(s) produced...
  • Page 4: Locating The Ultra Uv2 Unit

    NOTE: The use of multiple inlets/outlets will require additional unions. Use the plugs provided with the Ultra UV2 in the unused inlets and outlets. To install the unions onto the Ultra UV2 unit, glue and insert the unions spigot end into the inlet and outlet opening selected. Then, using the six plugs provided, glue the plugs into the remaining unused plumbing openings.
  • Page 5: Typical Plumbing Without And With Bypass

    If local codes require the pressure test to be higher than the max operating pressure on the silver label use the bypass (if the unit is plumbed with a bypass) to allow the Ultra UV2 to be only left at or below the max operating pressure.
  • Page 6: Parallel Plumbing Without And With Bypass

    To Heater or Pool MULTIPLE PORT PLUMBING FOR 3 LAMP UNITS WITHOUT AND WITH BYPASS Ultra UV2 3 lamp units require 2 inlets and 2 outlets be plumbed, see page 5. Optional Flow Switch Optional bypass valves fully closed...
  • Page 7: Electrical Bonding

    The electrical power rating for your Ultra UV2 unit is shown on the silver label located on the outside of the unit. (Fig. 3 on page 4) Make sure the supplied power meets the units electrical requirements. Connecting any power than that listed on the rating label will damage the unit and will VOID your limited warranty.
  • Page 8: System Start-Up

    Up to two additional lamps can WATER CHEMICAL BALANCE be added to a single lamp system. This is If you have installed your Ultra UV2 unit on any water accomplished easily by adding lamps and vessel other than fish ponds or ponds with live plants, or adding additional ballasts and lamps.
  • Page 9: Normal Operation

    Closed Ultra UV2 unit. This instruction applies to all systems with a single speed or with a variable speed pump. This type of damage is not covered under the factory warranty.
  • Page 10: Consumer Operating Instructions Quartz Tube Maintenance

    The quartz tube requires cleaning every 6 months to ensure optimum performance. 1. Turn off all power to the ULTRA UV2 unit and all other pool equipment. Unplug the unit from its power receptacle or turn OFF the circuit breaker that is the ULTRA UV2’s power source.
  • Page 11 ½ turn. Fig. 16 12. Turn power on to the Ultra UV2 unit. Turn pump on to check for leaks. Confirm that there are no leaks then turn off pump and power off to the unit. Reinstall lamps, spring clip and connect to ballast(s).
  • Page 12: Scheduled Uv Lamp(S) Replacement

    13,000 hours of operation they have reached the end of their useful life. LAMP REPLACEMENT PROCEDURE 1. Turn off all power to the ULTRA UV2 unit and all other pool equipment. Unplug the unit from its power receptacle or turn OFF the circuit breaker that is the ULTRA UV2’s power source.
  • Page 13: Troubleshooting

    Please note that the filter gauge does not indicate the pressure in the UV unit. c. If the operating pressure of the Ultra UV2 unit is below 2psi: Restrict flow in the return manifold to create enough back pressure to activate the pressure switch. If using a variable speed or multi speed pump, be sure that the high speed setting does not create excessive system back pressure once you’ve adjusted the flow.
  • Page 14 Reset the GFCI and if it does not trip, attach the electrical plug to a UV lamp. (One at a time if multiple lamps are present in your Ultra UV2 unit.) If it trips with the lamp lit, it indicates that a UV lamp is causing...
  • Page 15 THE ULTRA UV2 UNIT MAKES NOISE WHEN OPERATING This is an indication of the Ultra UV2 unit not being properly attached to a firm mounting base of concrete using bolts (not supplied) placed through the mounting holes in the Ultra UV2 unit base. Attach the Ultra UV2 unit correctly to a firm base as described in page 4.
  • Page 16: Ultra Uv2 Part Numbers

    • 1 Lamp unit requires 1 single lamp ballast • 2 Lamp unit requires 1 dual lamp ballast • 3 Lamp unit requires 1 single lamp ballast 1 dual lamp ballast ULTRA UV2 PART NUMBERS Paramount Part# Description 005-422-2009-11 Cover 005-422-9017-00 UV Lamp...

Table of Contents