  • Page 1 WATER PURIFYING SYSTEM INSTALLATION MANUAL 004-027-8818-00 REV 020416 US and Foreign patents and patents pending see www.1paramount.com/about/patents/ 295 East Corporate Place • Suite 100 • Chandler, AZ 85225 Toll Free: 1.800.621.5886 • Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com • www.1Paramount.com...
  • Page 2: Table Of Contents

    Signal Words and Symbols Used In This Manual This Owner’s Manual and Installation Guide contains specific precautions and symbols to identify safety- related information. You will find DANGER, CAUTION, WARNING and NOTICE symbols which require special attention. Please read them carefully and follow these precautions as indicated! They will explain how to avoid hazards that may endanger you or persons using or maintaining your pool or spa.
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS: READ COMPLETELY BEFORE PROCEEDING WITH INSTALLATION. SAVE THESE INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS CAUTION • Follow all applicable electrical codes. •...
  • Page 4: What Is Ozone And How Does It Work

    WHAT IS OZONE AND HOW DOES IT WORK • Ozone is created from oxygen using a simple yet powerful system of UV bulbs, to be used as a pure shock (oxidizer) for the swimming pool. • Ozone is injected into the pool water using the Clear O3 suction injection system, where the ozone enriched ®...
  • Page 5: Selecting Location & Mounting Unit

    SELECTING LOCATION & MOUNTING UNIT 1. Select a location on a wall near the pool Fig. 1 equipment or insert posts into the ground, which will be used to hang unit. The Clear O3 ® unit should be at least one (1) foot above maximum water level, and for extra safety the unit must be mounted higher than the filter.
  • Page 6: Making Electrical Connections

    3. Install an approved seal tight flex conduit (not Ground Lug included) rated for outdoor use, between the ClearO3 unit and power source. 4. The ClearO3 must be wired to a power source that Posts Ground Lug energizes the bulb when the pump that the air line is connected to is running.
  • Page 7: Alternate Electrical Connection For Multi-Speed Pump Without A Controller Or Time Clock

    Paramount has available an add-on paddle flow switch (Paramount part# 004-402-0010-00 or Grid Controls part # 57-F1-225-00W). The power is run through this switch and then to the ClearO3. The flow switch is plumbed in the main line of the pool return. When it senses flow the ClearO3 is turned on.
  • Page 8: Making Plumbing Connections

    Note: When the ClearO3 starts up, the light will be orange for around 10 seconds before it turns blue. If the light stays orange or red, turn the unit off immediately. Failure to do so will damage the ballast.
  • Page 9 4. OPTIONAL SUBMERGED EQUIPMENT NOT TO SCALE Fig. 13 INSTALLATION (Fig. 14) 2" PIPE To complete this installation option you will need a two 3/4" PIPE 3/4" PIPE way valve not included. 4.1 Install the two way valve on the inlet pipe to WATER LINE the pump suction.
  • Page 10: Plumbing For The Clear03

    The Clear03 ozone suction line will hook directly up to the bottom of the Clear03 and the other end to the injector with the check valve provided with the Clear03. No flow meter is needed or provided. NOTE: The ClearO3 unit must be mounted at least 1' above pool water level to prevent water from contacting electrical equipment.
  • Page 11: Plumbing The Clear03 With The Ultra Uv And Off Line Chlorine Feeder Using The Venturi Injector Method

    PLUMBING THE CLEAR03 WITH THE ULTRA UV AND OFF LINE CHLORINE FEEDER USING THE VENTURI INJECTOR METHOD When installing a Clear O3 and an Ultra UV with a Pressure Side Venturi Injector Manifold in the same pool system it is recommended, for maximum sanitation, that the Venturi Manifold be installed after the filter followed by the Ultra UV.
  • Page 12: Plumbing The Clear O3 And Ultra Uv With Ozone Introduced At The Pump And An Inline Chlorinator

    PLUMBING THE CLEAR O3 AND ULTRA UV WITH OZONE INTRODUCED AT THE PUMP AND AN INLINE CHLORINATOR When installing a Clear O3 and an Ultra UV in the same pool system, where the Ozone is piped into the pump strainer pot or into a standpipe before the pump suction, it is recommended that an air bleed be installed to remove excess air from the filter and return it to the pool piping downstream of the inline chlorinator, which should be the last component in the system.
  • Page 13: Setting Air Flow

    SETTING AIR FLOW Fig. 19 1. Clean filter and pump basket before setting airflow. 2. Turn the knob on the needle valve/flow meter clockwise to close valve completely. 3. Turn the power on to the pump. 4. Turn the knob on the needle valve/flow meter counter clockwise until the ball reads in the middle of the two lines on the flow meter.
  • Page 14: Bulb Replacement

    Mounting Instructions Fig. 21 1. Turn the power off to the pump. 2. Remove the pressure gauge from the filter. FILTER HEATER 3. Install the nipple into one end of the brass tee. CHLORINATOR 4. Install the pressure gauge by threading into the other end of the brass tee supplied.
  • Page 15 REPLACING UV BULB DO NOT TOUCH THE GLASS, HANDLE BY CERAMIC ENDS OF BULB Turn the power off to filtration system pump at Remove side cap. Grasp light bulb plug and pull circuit breaker. Remove three screws in left end light out about one inch.
  • Page 16: Troubleshooting & Service

    Clean filter then adjust airflow needle valve Filter empties and pump loses prime Replace check valve fitting at strainer pot Check power to the ClearO3, if you have power and Light bulb does not light the bulb still doesn’t light up, turn off the power and replace the bulb.
  • Page 17 (optional) (optional) (optional) (optional)
  • Page 19 Limited manufacturer’s warranty. 2 years on parts & 1 year on labor (labor only through authorized warranty service stations) POOL OWNER INFORMATION Name: Address: City: State: Zip Code: Telephone: Fax: E-mail: Pool Start-Up Date Purchased: Type of Pool (check one): Concrete Vinyl Fiberglass...
  • Page 20 NOTES...