WATER PURIFYING SYSTEM INSTALLATION MANUAL 004-027-8780-00 REV111313 US and Foreign patents and patents pending see www.1paramount.com/about/patents/ 295 East Corporate Place • Suite 100 • Chandler, AZ 85225 Toll Free: 1.800.621.5886 • Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com • www.1Paramount.com...
OPTIONAL SUBMERGED EQUIPMENT INSTALL ..............13 PLUMBING FOR THE CLEAR03 .....................15 USING THE VENTURI INJECTOR METHOD .................15 SETTING AIR FLOW ..........................16 EXTERNAL SAFETY AIR BLEED KIT INSTRUCTIONS (OPTIONAL) ........16 BULB REPLACEMENT .........................17 TROUBLESHOOTING & SERVICE ....................19 CLEAR O3 PART NUMBERS ......................21...
SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS: READ COMPLETELY BEFORE PROCEEDING WITH INSTALLATION. SAVE THESE INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: CAUTION: READ AND FOLLOW ALL INSTRUCTIONS WARNING: • Follow all applicable electrical codes. •...
• Ozone is created from oxygen using a simple yet powerful system of UV bulbs, to be used as a pure shock (oxidizer) for the swimming pool. • Ozone is injected into the pool water using the Clear O3 suction injection system, ®...
6. Mark the location for the two bottom brackets. (Fig. 2) 7. Remove the Clear O3® from the wall and install the wall anchors. 8. Place the Clear O3® unit back on the screws and line up the two lower brackets with the wall anchors. (Fig. 3) Fig.
MAKING ELECTRICAL CONNECTIONS 1. A licensed electrician should make all electrical connections. Make sure the unit is grounded by connecting to the pool equipments bond wire to comply with local electrical codes. 2. Turn off power to the filtration system pump at the circuit breaker. 3.
Page 7
Connect green ground wire to the time clock ground bar (Fig. 6A). The Clear O3® unit is set to 240VAC to be connected to the load side (Fig. 6B) of the filtration pump time clock.
(Fig. 5B) 6. Turn on power to filtration system pump. Check glow tube on the left front of the Clear O3®. A light blue light indicates lamp is lit and the unit should be producing ozone. (Fig. 9) WARNING: UV light produced by this unit is harmful to the eyes and may cause...
Page 9
THE CLEARO3 UNIT IS FACTORY SET TO 240VAC. THE CLEARO3 SHOULD BE WIRED TO RUN WITH THE FILTER PUMP WHICH CREATES THE AIR DRAW THROUGH THE UNIT NEEDED TO CREATE OzONE. DO NOT SET THE CLEARO3 TO RUN WHEN THE FILTER PUMP IS OFF. 1.
Fig. 15 Use the external ground lug to connect the ClearO3 to the pool pump bond wire. (Fig. 15) 10. Turn on power to the filtration system pump. Check the glow tube on the left front of the ClearO3. (Fig. 16) A light blue light Ground Lug indicates the lamp is lit and the unit should be producing ozone.
Page 11
(Fig. 18) 2.4 Install the combination needle valve flow meter on the bottom of the Clear O3® unit. (Fig. 19) 2.5 Install 3/8" OD x 1/4" ID tubing to compression end of check valve. (Fig. 20) 3.
5. Lay the 3/8 tubing along desired route to the compression fitting on the combination needle valve flow meter on the Clear O3® unit. 6. Connect the tubing to the compression fitting. (Fig. 22) 7. Use the provided wires ties to tie the loose tubing to the conduit or plumbing.
OPTIONAL SUBMERGED EQUIPMENT INSTALL New Installation using Paramount venturi Fig. 24 installation kit. TO COMPLETE THIS INSTALLATION YOU 2" x 2" x ¾" SLIP TEE WILL NEED THE FOLLOWING ITEMS (NOT INCLUDED) PRESSURE SIDE FROM FILTER - (2) 2” X 2” X ¾” SLIP TEE - (1) ¾”...
Page 14
(Fig 28) CHECK VALVE INSTALLED IN-LINE 3/8” OD X 1/4” IO TUBING SUCTION SIDE TO POOL PRESSURE SIDE FROM FILTER NOTE: CLEAR O3 MUST BE Fig. 27 MOUNTED 1' ABOVE WATER LEVEL COMPRESSION FITTING SUCTION SIDE TO POOL PRESSURE SIDE...
PLUMBING FOR THE CLEAR03 USING THE VENTURI INJECTOR METHOD The injector manifold must be installed in the pool’s main return line after the pool filter, heater, chlorinator and spa return. (Fig. 29A) shows the basic installation. Locate the appropriate section of the return line and install the injector manifold using PVC primer and glue on all mating surfaces.
THE PUMP RUNNING ON THE HIGHEST SPEED THAT WILL BE USED. 3. The Clear O3 flow meter is very sensitive and the red ball may drop down below the ‘normal’ marker after it has been set. If this happens on your unit, please be aware that this is normal.
test per instructions that air is vented from the filter when the pump is running. You must install an external air bleed if the filter is old, does not have an internal air bleed, there is a solar system on the pool or there is a robotic pressure side cleaner. MOUNTING INSTRUCTIONS 1.
Page 18
10. Replace side cap and three screws. 11. Turn on power to filtration system pump. 12. Check glow tube on the left front of the Clear O3®. A light blue light indicates lamp is lit and the unit should be producing ozone.
Clean filter then adjust airflow needle No air bubbles entering system or pool valve Filter empties and pump loses prime Replace check valve fitting at strainer pot Check power to Clear O3®, then Light bulb does not light replace bulb...
Wire Ties (4Pk) 005-402-3247-00 Flow Meter Kit Compression Nut 1/4" x 3/8" Anchor #10 Screw: 10 x 3/4" PHIL PH 005-402-1050-00 Clear O3 Adapter Pot Plug (Optional) 005-402-3824-00 Ballast & Filter AIR BLEED 006-402-3872-00 Clear O3 Air Bleed Kit (Optional) 005-252-3250-00...
Page 23
WARRANTY REGISTRATION A one (1) year warranty on Clear O3® parts shall be subject to the original owner, as stated in the “Other Related System Parts and Replacement Parts Limited Manufacturer’s 1-Year Warranty. ” POOL OWNER INFORMATION Name: Address: City:...