Comtech EF Data MBT-5000 User's Installation And Operation Manual page 120

L-band up/down converter system
Table of Contents

Advertisement

MBT-5000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Redundant
CRM=
1 byte
Mute Mode
LNA Current
CWE=
1 bytes
Window Enable
(BDC only)
Operating RF
FRE=xxxxx.xxx
9 bytes
Frequency
Global
GCC=
variable length
Converter
Configuration
(Note that all arguments are ASCII numeric codes between 48 and 57)
Query
Command or Query.
Determines how the offline unit handles the mute state during a redundant switchover condition.
If the redundant mute mode is off, the offline unit will be muted. If the redundant mute mode is
on, the offline unit's mute state will not be changed.
0 = Off
1 = On
Default Value: 0
Example: <1/CRM=0'cr'
>0001/CRM='cr''lf'
Command or Query.
Allows t he us er t o enable t he c urrent w indow al arm/fault. I f di sabled, t he L CW v alue w ill be
retained, but unused.
Default Value: 0
Example: <1/CWE=0'cr'
>0001/CWE='cr''lf'
Command or Query.
Sets, in MHz, valid Operating RF frequency.
For Ku BDC Tri-Band:
FRE values: 10950-11700 MHz a LO of 10000 MHz is activated
FRE values: 11700-12200 MHz a LO of 10750 MHz is activated
FRE values: 12250-12750 MHz a LO of 11300 MHz is activated
For Ku BDC Dual Band:
FRE values: 10950-11700 MHz a LO of 10000 MHz is activated
FRE values: 11700-12750 MHz a LO of 10750 MHz is activated
Example: FRE=11300.000'cr'
Note: Operating Frequency cannot be changed for the offline unit when in redundancy mode.
Command or Query.
Used to set up and query the global status of the BUC/BDC.
Example: GCC=aa.aa;b;ccccc.cc; 'cr' where:
aa.aa = attenuation in dB (ATT)
b = mute state, 0 = un-muted, 1 = muted (MUT)
ccccc.ccc = frequency in MHz (FRE, Ku BDC only, other units will display xxxxx.xxx)
Note: This command can only be queried for the offline unit when in redundancy mode.
Description of arguments
7–20
MN-MBT5000
Revision 4
Response to
Query
Response to query
Command
(Instruction
(Target to
Code and
Controller)
Qualifier)
CRM=
CRM?
CRM=x
CRM?
(same format as
Command
arguments)
CWE =
CWE?
CWE =x
CWE?
CWE *
(same format as
Command
arguments)
FRE=
FRE?
FRE=x....x
FRE?
FRE*
(See Description of
Arguments)
GCC=
GCC?
GCC=x....x
GCC?
GCC*
(See Description of
Arguments)
(Target to
Controller)

Advertisement