Serial-based Remote Product Management
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Number of
N/A
3 bytes
Unread stored
Statistics
Part Number
N/A
Various 1-96
bytes
Reboot
RBT=
1 byte
Retrieve
N/A
variable length
Configuration
Status
Reference
REF=
3 bytes
Oscillator
Tuning
(Note that all arguments are ASCII numeric codes between 48 and 57)
Query
Query only.
Unit returns the Number of stored Statistics that remain Unread, in the form xxx.
Example: NUS=126
Query only.
Returns the Comtech EF Data part number of the unit. This part number is the unit's DOTCODE
at the time it was manufactured. The DOTCODE may be up to 96 printable ASCII characters
long.
Example: <1/PNM?'cr'
>0001/PNM=MBT5003.350WRSW00'cr''lf'
Command only.
Soft Reboot
1 = Reboot System
Query only.
Used to Query the Configuration status of the unit
Example:
<1/RCS?'cr'
>0001/RCS='cr'
ESW=1'cr'
AFR=1'cr'
XRF=N/A'cr''lf'
Note: For XRF (External reference status):
N/A = no external reference;
05M = 5 MHz;
10M = 10 MHz.
XRF will always be N/A if the internal reference oscillator option is not installed.
Command or Query.
Adjusts the reference oscillator tuning voltage by sending a DAC value in the form xxx, where:
xxx is a numeric value from 0 to 255.
Default value: 087
Example: <1/REF=087'cr'
>0001/REF='cr''lf'
Note: This command sets the DAC value, but the actual Reference Oscillator tuning voltage can
be monitored using the RMS command.
Description of Arguments
Description:
Redundancy Mode
Auto Fault Recovery
External Reference Status
7–14
MN-MBT5000
Revision 4
Response to
Query
Response to query
Command
(Instruction
(Target to
Code and
Controller)
Qualifier)
N/A
NUS?
NUS=xxx
N/A
PNM?
PNM=x....x
(See Description of
Arguments)
RBT =
N/A
RBT=x
RBT?
(See Description of
RBT*
Arguments)
N/A
RCS?
RCS=x....x
(See Description of
Arguments)
REF=
REF?
REF=xxx
REF?
REF*
(Same format as
Command
arguments)
(Target to
Controller)