MBT-5000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Retrieve Next 5
N/A
75 bytes
unread stored
Events
(Note that all arguments are ASCII numeric codes between 48 and 57)
Query
Query only.
Unit returns the oldest 5 Stored Events which have not yet been read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body, where
Sub-body= ABCddmmyyhhmmss:
A being the fault/clear indicator.
F = Fault
C = Clear
I = Info
B being the fault type where:
1 = Base Unit
2 = Converter A
3 = Converter B
C is Fault Code numbers, where
For the base unit,
0 = No faults
1 = +12V Power Supply 1
2 = +12V Power Supply 2
3 = +5V Power Supply 1
4 = +5V Power Supply 2
5 = +7.8V Power Supply
6 = Flash Checksum
7 = FPGA Done
8 = External Ref Lock Detect
9 = Converter A1 Not Inserted
A = Converter B2 Not Inserted
B = Switch Fault
H = Power On
I = Power Off
J = Log Clear
K = Redundancy Config Change
For the Converter A and B,
1 = Synthesizer Lock Detect
2 = Heat-sink Temperature
3 = Low Forward RF Power
4 = LNA Current Supply
5 = High Temperature (Alarm)
If there are less than 5 events to be retrieved, the remaining positions are padded with zeros. If
there are no new events, the response is RNE*.
Description of Arguments
7–16
MN-MBT5000
Revision 4
Response to
Query
Response to query
Command
(Instruction
(Target to
Code and
Controller)
Qualifier)
N/A
RNE?
RNE={CR}ABCddmm
yyhhmmss{CR}ABCd
dmmyyhhmmss{CR}A
BCddmmyyhhmmss{
CR}ABCddmmyyhhm
mss{CR}ABCddmmyy
hhmmss
(See Description of
Arguments)
(Target to
Controller)