Comtech EF Data MBT-5000 User's Installation And Operation Manual page 118

L-band up/down converter system
Table of Contents

Advertisement

MBT-5000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Set RTC Time
TIM=
6 bytes
Time Protocol
1 byte
TPE=
Enable
Time Protocol
15 bytes
TPS=
Server
(Note that all arguments are ASCII numeric codes between 48 and 57)
Query
Command or Query.
Indicates the time from midnight, in the form hhmmss, where:
hh = hours, between 00 and 23;
mm=minutes between 00 and 59, and
ss= seconds between 00 and 59.
Example: <1/TIM=231259'cr'
>0001/TIM='cr''lf'
(time = 23 hours, 12 minutes and 59 seconds since midnight)
Command or Query.
Used to enable or disable the Time Protocol, where:
0 = Time protocol disabled
1 = Time protocol enabled
Example: TPE=1 (Time protocol enabled)
Command or Query.
Used to set the Time Server IP address for the Unit Tx Ethernet management port, in the format:
xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx is the Time server IP address
Example: TPS=192.168.001.005
Description of Arguments
7–18
MN-MBT5000
Revision 4
Response to
Query
Response to query
Command
(Instruction
(Target to
Code and
Controller)
Qualifier)
TIM =
TIM?
TIM=xxxxxx
TIM?
TIM *
(Same format as
Command
arguments)
TPE =
TPE=x
TPE?
TPE?
(See Description of
Arguments)
TPS=
TPS=
TPS?
TPS?
xx.xxx.xxx.xxx.yy
(See Description of
Arguments)
(Target to
Controller)

Advertisement

Table of Contents
loading

Table of Contents