MBT-5000 L-Band Up/Down Converter System
Serial-based Remote Product Management
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Enable
ESA=
1 byte
Statistics
Averaging
Enable
ESL=
1 byte
Statistics
Logging
Enable
ESW=
1 byte
Redundancy
Switch Mode
Retrieve
N/A
variable length
Firmware
Number
(Note that all arguments are ASCII numeric codes between 48 and 57)
Query
Command or Query.
Enables or D isables averaging of statistics data at a r ate of once per second for 10 s econd. If
disabled, burst values will be logged instead of averaged values.
0 = Disabled
1 = Enabled
Default Value: 0
Example: <1/ESA=0'cr'
>0001/ESA='cr''lf'
Command or Query.
Enables or Disables the statistics logging function.
0 = Disable
1 = Enable
Default Value: 0
Example: <1/ESL=1'cr'
>0001/ESL='cr''lf'
Command or Query.
Turns ON or OFF the redundancy state, where:
0 = Off
1 = On
Default value: 1
Example: <1/ESW=1'cr'
>0001/ESW='cr''lf'
Query only.
Returns the firmware type loaded into the unit.
i = Bulk Image Number (1 or 2)
a = Firmware Image
b = Firmware Revision
c = Firmware Date
Description of Arguments
7–10
MN-MBT5000
Revision 4
Response to
Query
Response to query
Command
(Instruction
(Target to
Code and
Controller)
Qualifier)
ESA=
ESA?
ESA=x
ESA?
(Same format as
Command
arguments)
ESL=
ESL?
ESL=x
ESL?
(Same format as
Command
arguments)
ESW=
ESW?
ESW=x
ESW?
ESW *
N/A
FRW?i
FRW={CR}Boot:{CR}
abc{CR}Bulki:{CR}abc
{CR}abc
(See Description of
Arguments)
(Target to
Controller)