INSTALLATION
The ignition sense cable HKN9327 allows the CM5000 to be turned on and off by the vehicle ignition
switch.
To install the cable, carry out the following steps.
1.
Connect the stripped lead of the fuse holder cable only to an ignition switched terminal of the
fuse block. Use the supplied terminal or any other suitable terminal.
2.
Mount the fuse holder using the mounting hole, and dress wires as required.
3.
Cut the thin cable to the required length, crimp the supplied red lead to the stripped lead of
the thin cable, and connect it to the blue terminal of the fuse holder cable.
4.
Connect the other end of the ignition sense thin cable to pin 4 of the junction box terminal.
5.
Insert the provided fuse into the fuse holder and close the cover.
CM5000 TETRA Mobile Repeater/Gateway Installation Manual
5
4
Figure 14 Connectors on the Junction Box (Rear Panel)
7
6
4 = Connector for programming
cable FLN 9636
5 = Connector for accessory
connector kit GMBN1021
6 = Connector for adapting a
laptop via RS232 cable
7 = TELCO-connector for fist
microphone (GMMN4063_) or
telephone style handset
(GMUN1006_)