Relevant Technical Data - Danfoss PVG 16 Service And Parts Manual

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Service and Parts Manual
PVG 16/32/128/256
Installation
PVEO/PVEO-CI control specifications
Description
Supply Voltage (Udc)
Current consumption
PVEA/PVEA-CI/PVEA-F control specifications
Supply voltage (Udc)
Signal voltage (Us)
Current consumption
Input impedance
Input capacitance
Operating conditions
Pilot pressure
Oil consumption
Storage temperature
Operating temperature
Oil viscosity
Oil cleanliness
©
Danfoss | October 2018
PVG 16 technical data overview
Only an overview of technical data is shown below; for comprehensive data, please see the Technical
Information document for PVG 16.
Type
Rated
Range
Max. ripple
Typical
Rated
Range
Max. ripple
Neutral
Q: P → A
Q: P → B
@ 12 Vdc
@ 24 Vdc
Rated
Rated
Nominal
Minimum
Maximum
Neutral
Locked position
Actuating
Ambient
Ambient
Operating range
Minimum
Maximum
Minimum
PVG 16 connector variants
PVG 16 connector variants for PVEO, PVEA, PVEO-CI, PVEA-CI, PVEA-F with pin layout information.
Value
12 Vdc
24 Vdc
11 to 15 Vdc
22 to 30 Vdc
5%
5%
320 mA
160 mA
11 to 32 Vdc
11 to 32 Vdc
5%
0.5 Udc
0.25 Udc
0.75 Udc
320 mA
170 mA
12 kΩ
100 µF
13.5 bar [196 psi]
10.0 bar [145 psi]
15.0 bar [218 psi]
0.04 l/min [0.01 US gal/min]
0.04 l/min [0.01 US gal/min]
0.6 l/min [0.16 US gal/min]
-50 to +90°C [-58 to +194°F]
-40 to +90°C [-40 to +194°F]
2
12 to 75 mm
/sec [65 to 347 SUS]
2
4 mm
/sec [39 SUS]
2
460 mm
/sec [2128 SUS]
18/16/13 (according to ISO 4406)
AX284661889190en-000101 | 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvg 32Pvg 128Pvg 256