Pvhc - Danfoss PVG 16 Service And Parts Manual

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Service and Parts Manual
PVG 16/32/128/256
Installation
Parameter
Current
Pressure control range
Description
Controller output current range
Coil resistance
*
Pilot pressure (over tank)
Control pressure
38 |
©
Danfoss | October 2018
PVHC for PVG 32 installation
The seal in the PVHC connector and the seals for individual conductors are crucial for correctly sealing the
connector.
PVHC for PVG 32
8 ± 0.5 Nm
[70 ± 4.4 lbf·in]
5 [0.20]
PVHC for PVG 32 connector
DEUTSCH (left) and AMP (right) connectors
U
(B)
DC
U
(A)
DC
12 V
1 - 1500 mA
5 to 15 bar [72.5 to 217.5 psi]
PVHC for PVG 32 technical data
12 V
24 V
12 V
24 V
Nominal
Minimum
Maximum
Range
(B)
U
DC
(A)
U
DC
Control range
24 V
0 - 750 mA
Value
0 – 1500 mA
0 – 750 mA
4.72 Ω ± 5%
20.8 Ω ± 5%
25 bar [363 psi]
21 bar [305 psi]
25 bar [363 psi]
5 - 15 bar [72.5 - 217.5 psi]
AX284661889190en-000101