Pvph And Ls Connections; Pvpe Technical Data - Danfoss PVG 120 Service Manual

Proportional valve group
Hide thumbs Also See for PVG 120:
Table of Contents

Advertisement

Service Manual
Installation

PVPH and LS connections

PVPE technical data

PVG 120 Proportional Valve Group
Max. tightening torque for PVPH and LS
Sealing
Steel washer
Cupper washer
Aluminium washer
Cutting edge
PVPE technical data
Max. operation pressure
Max. pressure drop a an flow of 0.20 l/min. [0.053 US gal/min]
Oil temperature
Recommended temperature
(inlet temperature)
Min. temperature
Max. temperature
Max. coil surface temperature
Ambient temperature
Oil viscosity
Operating range
Min. viscosity
Max. viscosity
Response time for pressure relief to tank
Enclosure to. IEC 529
Rated voltage
Max. permissible deviation from rated supply voltage
Current consumption at
at 22°C [72°F] coil temperature
rated voltage
at 85°C [230°F] coil temperature
at 22°C [72°F] coil temperature
at 85°C [230°F] coil temperature
520L0247 • Rev JA • May 2014
Threads, DS/ISO 228/1
PVPH: G ¼
3
LS: G
8
PVPH: G ¼
3
LS: G
8
PVPH: G ¼
3
LS: G
8
PVPH: G ¼
3
LS: G
8
350 bar [5085 psi]
1.2 bar [17 psi]
30 to 60°C [86 to 140°F]
–30°C [–22°F]
90°C [194°F]
155°C [311°F]
–30 to 60°C [–22 to 140°F]
12 to 75 mm²/s [65 to 347 SUS]
4 mm²/s [39 SUS]
460 mm²/s [2128 SUS]
600 ms
IP 65
12 V
± 10 %
1.55 A
1 A
19 W
12 W
Max. tightening torque
40 Nm [350 lbf·in]
60 Nm [530 lbf·in]
20 Nm [180 lbf·in]
35 N•m [310 lbf·in]
30 N•m [270 lbf·in]
40 Nm [350 lbf·in]
40 Nm [350 lbf·in]
60 Nm [530 lbf·in]
24 V
± 10 %
0.78 A
0.5 A
19 W
12 W
21