Danfoss PVG 16 Service And Parts Manual page 33

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Service and Parts Manual
PVG 16/32/128/256
Installation
PVED-CC control specification
Description
Supply Voltage (UDC)
Current consumption
Power consumption
PVED-CC operating conditions
Description
Pilot Pressure
Oil Consumption
Storage Temperature
Operating Temperature
Oil Viscosity
Oil Cleanliness
Grade of enclosure
©
Danfoss | October 2018
PVED-CC series 5 for PVG 32 technical data
Type
Nominal
Minimum
Maximum
@ 12 V
@ 24 V
@ 12 V
@ 24 V
Type
Nominal
Minimum
Maximum
Neutral
Locked Position
Actuating
Ambient
Ambient
Operating Range
Minimum
Maximum
Maximum
Value
11 to 32 VDC
9 V
36 V
560 mA
300 mA
6.2 W
7.2 W
Value
13.5 bar [196 psi]
10.0 bar [145 psi]
15.0 bar [218 psi]
0 l/min [0 US gal/min]
0 l/min [0 US gal/min]
0.7 l/min [0.184 US gal/min]
-40 to +90°C [-40 to +194°F]
-30 to +60°C [-22 to +140°F]
12 – 75 cSt [65 – 347 SUS]
4 cSt [39 SUS]
460 cSt [2128 SUS]
18/16/13 (according to ISO 4406)
IP 66