Pvhc - Danfoss PVG 16 Service And Parts Manual

Proportional valve group
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Service and Parts Manual
PVG 16/32/128/256
Installation
Controller output current range
Coil resistance
*
Pilot pressure (over tank)
Control pressure
Max. tank pressure
Temperature range
Oil viscosity
©
Danfoss | October 2018
PVHC for PVG 128/256 installation
5 [0.2]
8 ± 0.5 N•m
[70 ± 4.4 lbf•in]
PVHC for PVG 128/256 connector
The seal in the PVHC connector and the seals for individual conductors are crucial for correctly sealing the
connector.
DEUTSCH Version
(B) Udc
(A) Udc
PVHC for PVG 128/256 technical data
12 V
24 V
12 V
24 V
Nominal
Minimum
Maximum
Range
Port T Static
Port T Dynamic
Ambient
Medium
Operating range
Minimum
Maximum
AMP Version
(B) Udc
(A) Udc
1 - 1500 mA
0 - 750 mA
4.72 Ω ± 5%
20.8 Ω ± 5%
25 bar [363 psi]
21 bar [305 psi]
25 bar [363 psi]
5 - 15 bar [72.5 - 217.5 psi]
25 bar [363 psi]
30 bar [435 psi]
-30°C → 80°C [-22°F → 176°F]
-20°C → 80°C [-4°F → 176°F]
12 → 75 mm2/s [65 → 347 SUS]
2
4 mm
/s [39 SUS]
2
400 mm
/s [2130 SUS]
AX284661889190en-000101 | 49