Reference
Parameter
<mode>
<save>
Example
$PQEPE,W,1,1*2A
$PQEPE,W,OK*02
NOTE
The command will be effective immediately after setting.
2.4. PQ1PPS Set the Type and Pulse Width of 1PPS Output
PQ1PPS Set the Type and Pulse Width of 1PPS Output
Write Command
$PQ1PPS,W,<type>,<width>*Checksu
m<CR><LF>
Reference
Parameter
<type>
GNSS_SDK_Commands_Manual
<EPE_vert> Estimated vertical position error
Example
$PQEPE,5.3050,3.2000*53
Operation
0
Disable the URC including EPE data
1
Enable the URC including EPE data
Save operation
0
Parameter is not saved, and ineffective after restart
1
Parameter is saved in flash, and effective after restart
//Enable the URC including EPE data, and save parameters into flash
//Set OK
Response
$PQ1PPS,W,OK*Checksum<CR><LF>
If there is any error, response:
$PQ1PPS,W,ERROR*Checksum<CR><LF>
The type of 1PPS output
0
Disable 1PPS output
GNSS SDK Commands Manual
Confidential / Released
GNSS Module Series