Error Code
IBMTOKEN-xx-223
IBMTOKEN-xx-224
Explanation and Action
The adapter cannot be opened in AutoSense mode if it
is the only active station on the network.
Explanation:
The DataRate configuration parameter is set
to AUTO (which is also the default value if the
parameter is not specified), but the adapter is
the first station to open on the Token-Ring
network.
User Action:
This adapter is designed to not open onto the
attached Token-Ring network if it is configured
to use AutoSense detection and if it would
have been the first active ring station.
The possible remedies are to try connecting
again at a later time when at least one other
ring station is active on the network (such as
a network server), or to change the
configuration value so that the DataRate
parameter is set to a specific ring-speed value
of M16 or M4 and restart the computer.
Note that setting a specific value of M16 or
M4 for the DataRate parameter will cause this
adapter to establish the operational speed of
the Token-Ring network if it is still the first
active ring station, so consult with your local
network administrator if necessary.
Check the adapter installation instructions for
additional information on setting the DataRate
parameter.
Port xxx : The adapter attempted to perform a Remote
Program Load but failed monitor contention.
Explanation:
The adapter was opened as a Remote
Proram Load (RPL) client, but was unable to
locate an RPL server on the network.
User Action:
Make sure that there is an active Remote
Program Load server on the network and that
it is configured to recognize this adapter's
network address.
Appendix B. Problem Determination
57