Checking Pilot And Burner Flames; Glowing Ceramic Roof Panel - Valor Legend G3.5 700JN Owner's Manual

Direct vent gas insert fireplace, natural/propane gas
Table of Contents

Advertisement

Checking Pilot and Burner Flames

A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
Correct Flame Picture
Pilot Flame can be
seen between logs
Logs
Correct Flame Picture
Pilot Flame can be
seen between twig
and rocks
Rocks
Thermocouple
Probe must be
in Flame
Servicing & Maintenance
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that dirt, snow, insects, leaves, shrubs, trees do
not obstruct it.
Examine the whole vent system regularly. We
recommend annually.

Glowing Ceramic Roof Panel

Due to the high effi ciency compact nature of this
product, you may notice some glowing on the ceramic
roof panel in the area indicated below. The amount of
glow will vary slightly with diff erent fuel eff ects and vent
lengths and is unavoidable without sacrifi cing some
effi ciency. Through testing we have determined this
glow will not impact the longevity of the appliance.
Pilot
Flame
OWNER'S
INFORMATION
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legend g3.5 700jp

Table of Contents