ABB PROFIBUS FEX100-DP User Manual page 60

Watermaster electromagnetic flowmeter
Table of Contents

Advertisement

WaterMaster
Electromagnetic flowmeter
Abs. Idx /
Rel. Idx
UNUSED
72 / 56
Unused parameter.
ELECTRODE_2_RESISTANCE
73 / 57
Resistance of electrode 2.
Unit: kOhm
BACK_OFF_VOLTAGE
74 / 58
Transmitter internal backoff voltage.
Unit: V
COIL_AND_CABLE_RESISTANCE
75 / 59
Resistance of coil and cable.
Unit: Ohm
COIL_INDUCTANCE
76 / 60
Inductance of the sensor coil.
Unit: mH
SENSOR_INDUCTANCE_SHIFT
77 / 61
Percentage shift in coil inductance.
Unit: %
TRANSMITTER_AVERAGE_GAIN_SHIFT
78 / 62
Percentage shift in transmitter span calibration.
Unit: %
Table 2.14 Slot 12 – Transducer Block 5 – Diagnostics (Continued)
58
Variable Name / Brief Description
Access /
Data Type
Size
Store
Usage /
Transport
101
5
D
r / O / a
101
5
D
r / O / a
101
5
D
r / O / a
101
5
D
r / O / a
101
5
D
r / O / a
101
5
D
r / O / a
2 Parameter Tables
Default
0
0
0
0
0
0
IM/WMPBST–EN Rev. B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents