Electromagnetic flowmeter
Abs. Idx /
Variable Name / Brief Description
Rel. Idx
MASK_OVERRANGE_103
Mask for the Overflow 103% alarm.
63 / 47
0: Disabled
1: Enabled
UNUSED
64 / 48
Unused parameter.
UNUSED
65 / 49
Unused parameter.
FLOWRATE_LIMIT_MIN_ALARM
Flowrate for min. flow alarm.
66 / 50
Min: 0
Max: 130
Unit: %
FLOWRATE_LIMIT_MAX_ALARM
Flowrate for max. flow alarm.
67 / 51
Min: 0
Max: 130
Unit: %
DATA_EXCHANGE_ACTIVE
Flag set when the device is cyclically exchanging data with a master.
68 / 52
0: Inactive
1: Active
Table 2.2 Slot 0 – Physical Block (Continued)
8
Access /
Data Type
Size
Store
Usage /
Transport
Unsigned 8
1
S
r,w / C / a
Float
4
S
r,w / C / a
Float
4
S
r,w / C / a
Unsigned 8
1
D
r / C / a
2 Parameter Tables
Default
Enabled
0
110
Inactive
IM/WMPBST–EN Rev. B