WaterMaster
Electromagnetic flowmeter
Abs. Idx /
Variable Name / Brief Description
Rel. Idx
SOFTWARE_REVISION
24 / 8
Revision number of the device firmware.
HARDWARE_REVISION
25 / 9
Revision number of the device hardware.
DEVICE_MAN_ID
26 / 10
Unique identifier of the device manufacturer.
DEVICE_ID
27 / 11
Manufacturer specific identification of the device.
DEVICE_SER_NUM
28 / 12
Unique transmitter identification number.
DIAGNOSIS
29 / 13
Standard diagnostic information for the device.
DIAGNOSIS_EXTENSION
30 / 14
Extended diagnostic information for the device.
DIAGNOSIS_MASK
31 / 15
Mask for Diagnostic information bytes.
DIAGNOSIS_MASK_EXTENSION
32 / 16
Mask for Extended Diagnostic information bytes.
DEVICE_CERTIFICATION
33 / 17
Available certifications for the device.
WRITE_LOCKING
Software write locking for the PROFIBUS interface.
34 / 18
0: Write Locking Enabled
2457: Write Locking Disabled
FACTORY_RESET
Reset functions to the device EEPROM Device and Bus Address
Changes to this parameter cause the instrument to reboot.
35 / 19
1: Reset ROM Defaults
2506: Soft Reset
2712: Default Station Address
DESCRIPTOR
36 / 20
Device descriptive text.
DEVICE_MESSAGE
37 / 21
Device message text.
Table 2.2 Slot 0 – Physical Block (Continued)
4
Access /
Data Type
Size
Store
Usage /
Transport
VisibleString
16
Cst
r / C / a
VisibleString
16
Cst
r / C / a
Unsigned 16
2
Cst
r / C / a
VisibleString
16
Cst
r / C / a
VisibleString
16
Cst
r / C / a
OctetString
4
D
r / C / a
OctetString
6
D
r / C / a
OctetString
4
Cst
r / C / a
OctetString
6
Cst
r / C / a
VisibleString
32
Cst
r / C / a
Unsigned 16
2
N
r,w / C / a
Unsigned 16
2
S
r,w / C / a
OctetString
32
S
r,w / C / a
OctetString
32
S
r,w / C / a
2 Parameter Tables
Default
'?
'
'?
'
26
'FEX100–DP'
1
0
0
0
0xFE,0xBF,0x67,0x
FF,0xBD,0x01
'
'
Write Locking
Disabled
'
'
'
'
IM/WMPBST–EN Rev. B