ABB PROFIBUS FEX100-DP User Manual page 57

Watermaster electromagnetic flowmeter
Table of Contents

Advertisement

WaterMaster
Electromagnetic flowmeter
Abs. Idx /
Rel. Idx
SIMULATION_LOGIC_3
State to simulate on Logic Output 3.
31 / 15
0: Off
1: On
ELECTRODE_RESISTANCE_ALARM_MAX_EP
Upper limit of electrode resistance.
32 / 16
Min: 0
Max: 1000
Unit: kOhm
ELECTRODE_RESISTANCE_ALARM_MIN
Lower limit of electrode resistance.
33 / 17
Min: 0
Max: 1000
Unit: kOhm
ELECTODE_VOLTAGE_POSITIVE_LIMIT
34 / 18
Upper limit of electrode voltage.
Unit: V
ELECTRODE_VOLTAGE_NEGATIVE_LIMIT
35 / 19
Lower limit of electrode voltage.
Unit: V
ELECTRODE_VOLTAGE_DIFFERENTIAL_LIMIT
36 / 20
Upper limit of differential electrode voltage.
Unit: V
COIL_CURRENT_ALARM_BAND
37 / 21
Percentage shift in coil current allowed before alarm.
Unit: %
COIL_OPEN_CIRCUIT_RESISTANCE_LIMIT
38 / 22
Upper limit of coil resistance range.
Unit: Ohm
COIL_SHORT_CIRCUIT_RESISTANCE_LIMIT
39 / 23
Lower limit of coil resistance range.
Unit: Ohm
SIMULATION_VOLUME_FLOW_RANGE_LOWER
40 / 24
Lower limit for internal simulated volume flowrate values.
Table 2.14 Slot 12 – Transducer Block 5 – Diagnostics (Continued)
IM/WMPBST–EN Rev. B
Variable Name / Brief Description
Access /
Data Type
Size
Store
Usage /
Transport
Unsigned 8
1
D
r,w / C / a
Float
4
S
r,w / C / a
Float
4
S
r,w / C / a
Float
4
D
r / C / a
Float
4
D
r / C / a
Float
4
D
r / C / a
Float
4
D
r / C / a
Float
4
D
r / C / a
Float
4
D
r / C / a
Float
4
D
r / C / a
2 Parameter Tables
Default
Off
200
0.1
1.8
–1.5
0.5
1
500
5
0
55