Menu Description
Menu
78.
Cold start rinse
1.5 Liter
79.
Boilerpurge
Off
80.
Standby Temp.
not active
81.
Water
normal
82.
Option counter
On
83.
Powersavemode
Off
84.
R-Temp. high
not active
© 2009 by Thermoplan AG, Subject to change
Technical Manual
By pressing thr „Minus" or „Plus" key in the parameter Cold Start Rinse the water quantity during
a cold start rinse can be programmed. The basic factory default value is 1.5 liter. The water quantity
can be adjusted between „not Active" and „2.0 liter".
Note:
1) The Cold Start Rinse is only activated after a Cold Start
2) It is possible to interrupt the Cold Start Rinse by pressing the „STOP"-key.
Once interrupted, the Cold Start Rinse has to be done again from the beginning.
3) It is not possible to cancel and skip the Cold Start Rinse.
By pressing the „Minus" or „Plus" key in the parameter Boiler Purge "ON/OFF" it can be program-
med whether the autoamtic boiler purge shall be activated.
On:
If the puck drawer needs to be emptied, (display will read Empty Drawer), every time after the
drawer is put back into the machine the dispaly will read „Boiler Purge /Press Clean Key. The water
in the steam boiler will be replenished with fresh water during 30 seconds running water out of the
hot water tap.
During the boiler purge function no coffee products can be produced.
This function is not active when the coffee grounds are set to Not-Active/OFF
The factory default setting is Off
In this parameter the Standby Temperature can be set from Not-Active to 15 degrees C.
If no coffee is dispensed for 3 minutes after the last coffee was produced the Standby Temperature
is activated, i.e the boiler temperature is increased by the value programmed to make sure the next
coffee beverage has the correct temperature.
By pressing the „Minus" or „Plus" key in the parameter Water normal/Tank the type of water
connection can be selected:
- Normal means that the tea and internal rinse is activated by line pressure
- Tank means that the line pressure will be supplied by an external booster water pump.
The factory default value is set at normal
Note:
The location of the water tank must not be below the level of the coffee machine.
At the moment this menu has no function.
This menu must not be changed!
In this menu you can set the maximum temperature of the refridgerator by pressing the „Minus" or
„Plus" key. If the value is reached, the display will show a warning message.
Note:
The temperature of the refridgerator cannot be set. This is only a warning message when the set
temperature is reached!
Description
REV-4
SECTION 3
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
3.39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents