Menu Description
Menu
66.
Milklevel Mode
Warning
67.
Debit / Credit
Off
68.
Machine type
normal
69.
keyboard
12 key
70.
Service interval
50000p
© 2009 by Thermoplan AG, Subject to change
Technical Manual
In this menu the milklevel mode can be set to change the reaction of the machine when the milk
reaches a low level. The following 2 settings are available:
Warning: (Default setting)
By reaching the upper level the machine shows „Milk low", the dispensed product will be finished
and milk products are still available.
By reaching the lower level the dispensed product is cancelled and all milk products are locked.
Milk has to be refilled.
Lock:
By reaching the upper level the dispensed product will be finished, afterwards all milk products are
locked. Milk has to be refilled.
The machine has galvanically separated serial a connection. In the parameter Debit/Credit by
pressing the „Minus" or „Plus" key the following option can be selected:
Off: The machine shows product control through daily counter
kMI: Connection via interface in beverage systems in binary mode
kBOX: Aconnection via interface on cashier systems (CT & CTS: „CBOX")
Card: Waiter Card
Saldo: Cash-Card
MDB-T: Connection via interface MDB2 on cashier systems, coin changer etc.
kMIpara: Connection via interface in beverage systems in parallel mode
The basic default value is Off.
By pressing the „Minus" or „Plus" key in the parameter Machine type the mode of operation
Normal or Self- Service can be programmed: The basic factory default is set to Normal.
- Normal
- Selfservice
Note:
In case a coin validator is connected to the coffee machine it makes sense to set the machine to
operation „Self-Servce". With this selection the keys M2, 2X, Clean as well as the POD functions
will be disabled.
By pressing the „Minus" or „Plus" key in the parameter „Keyboard" the amount of active keys can
be programmed. You can choose between 12 (all) or 8 keys.
By pressing the „Minus" or „Plus" key in the parameter Service Interval the service level can be
programmed in number of 1,000 cycles. The basic factory default is set at 50'000 cycles. After
the service on the coffee machine is performed the service counter must be reset by pressing the
Clear-Key 3 times rapidly. The display confirms that the counter has been reset to zero by display
the message "OK".
Note:
The coffee machine must be serviced regularly. It must be descaled and checked for proper functio-
nality as well as that it corresponds to all safety regulations. Basically the periodic maintenance of
the coffee machine depends on its use but must be done at least every six months by an authorized
service technician.