Thermoplan Black&White3 CT Technical Manual page 38

Programming fox1
Hide thumbs Also See for Black&White3 CT:
Table of Contents

Advertisement

Menu Description
Menu
71.
Rinse interval
Coffee Off
72.
Rinse interval
Milk 5min
73.
Cleaning alarm
1000
74.
Powermanagement
On
75.
Motorswitch
Switch
76.
Mill position
358
77.
Voltagecontrol
not active
© 2009 by Thermoplan AG, Subject to change
Technical Manual
By pressing the „Minus" or „Plus" key in the parameter Rinse Interval it can be programmed after
which standby time an automatic short rinse cycle should be activated. The adjustment range can
be set between Not Active up to 60 minutes. The basic factory default is
for coffee: „Off"
for milk: „5min".
Note:
If no milk product is produced for 5 minutes starting from the last cycle an automatic quick rinsing
is activated. If another 5 minutes elapse a quick internal rinse is automatically activated before the
next following product is dispensed.
By pressing the „Minus" or „Plus" key in the parameter Cleaning Alarm it can be programmed
after how many coffee cycles the machine should prompt the Message Clean Appliance to perform
a cleaning cycle. The basic value can be set between Not Active up to 1'000 cycles.
By pressing the „Minus" or „Plus" key in the parameter Power Management the setting Power
Management can be activated.
„Powermanagement On"
The heating of the coffee boiler and the steam boiler/milk foamer is individually activated, i.e. the
coffee boiler heats up first and when reaching the programmed temperature the steam boiler and
the foamer heating is activated.
„Powermanagement Off"
All heating elements of the coffee boiler, steam boiler and foamer are activated simultaneously,
(CTS automatic default setting)
By pressing the „Minus" or „Plus" key in the parameter „Motorswitch" you can choose between
„Switch" (Default) and „Magnetic". This function is applied for a future project and must not be
changed!
By pressing the „Minus" or „Plus" key in the parameter Mill Position the mill position of the brew
chamber can be adjusted. Range can be adjusted between 205 - 460. In order to verify the correct
Mill Position, press the Double Product Key and the brew chamber moves from the micro switch
to the grind position. The correct adjustement of the grind position can be verified if the markings
on the outside of the brew chamber and the grinder head are completely aligned. If the Double
Product Key is pressed again the brew chamber moves back to the home position, (micro switch)
By pressing the „Minus" or „Plus" key in the parameter Voltage Control the voltage control
0-30% can be adjusted. The operation will be interrupted if the voltage falls below or above the
set percentage. As soon as the voltage is back within the programmed tolerance the machine is
operational again and the display reads „Ready". If the machine is not in Ready mode the display
reads either Voltage Too High or Voltage too Low, respectively, while showing the voltage difference
as a percentage.
If the voltage changes during a brew cycle out of the programmed tolerance level the cycle will be
completed before the machine will display the error message.