Download Print this page

Step 3-Technical Data - Eaton M-Max series Quick Start Manual

Variable frequency drives. pump application
Hide thumbs Also See for M-Max series:

Advertisement

Step 3—Technical data
Step 3—Technical data
Table 4. Technical data
Part Number
Power Connection Voltage: 1 AC 115V, 50/60 Hz (94 – 132V ± 0%, 45 – 66 Hz ± 0%)
MMX11AA1D7...
MMX11AA2D4...
MMX11AA2D8...
MMX11AA3D7...
MMX11AA4D8...
Power Connection Voltage: 1 AC 230V, 50/60 Hz (177 – 264V ± 0%, 45 – 66 Hz ± 0%)
MMX12AA1D7...
MMX12AA2D4...
MMX12AA2D8...
MMX12AA3D7...
MMX12AA4D8...
MMX12AA7D0...
MMX12AA9D6...
Power Connection Voltage: 3AC 230V, 50/60 Hz (177 – 264V ± 0%, 45 – 66 Hz ± 0%)
MMX32AA1D7...
MMX32AA2D4...
MMX32AA2D8...
MMX32AA3D7...
MMX32AA4D8...
MMX32AA7D0...
MMX32AA011...
Power Connection Voltage: 3 AC 400V/460V, 50/60 Hz (323 – 528V ± 0%, 45 – 66 Hz ± 0%)
MMX34AA1D3...
MMX34AA1D9...
MMX34AA2D4...
MMX34AA3D3...
MMX34AA4D3...
MMX34AA5D6...
MMX34AA7D6...
MMX34AA9D0...
MMX34AA012...
MMX34AA014...
Notes
1
Rated motor currents for normal four-pole internally cooled and surface-cooled three-phase asynchronous motors
(1500 rpm at 50 Hz, 1800 rpm at 60 Hz).
2
Calculated motor rating (no normalized value). The mains voltage of 115V is raised to 230V (output voltage) through
an internal voltage double connection.
3
Allocated motor output at a maximum ambient temperature of +40ºC and a maximum pulse frequency of 4 kHz.
4
Operation with reduced load torque (about –10% MN).
6
M-Max Series VFD pump application MN040046EN—June 2018 www.eaton.com
Rated
Operational
Overload
Current
Current (150%)
I e
I e150
[A]
[A]
1.7
2.6
2.4
3.6
2.8
4.2
3.7
5.6
4.8
7.2
1.7
2.6
2.4
3.6
2.8
4.2
3.7
5.6
4.8
7.2
7.0
10.5
9.6
14.4
1.7
2.6
2.4
3.6
2.8
4.2
3.7
5.6
4.8
7.2
7.0
10.5
11.0
14.4
1.3
2.0
1.9
2.9
2.4
3.6
3.3
5.0
4.3
6.5
5.6
8.4
7.6
11.4
9.0
13.5
12.0
18.0
14.0
21.0
Assigned Motor Rating
P (230V, 50 Hz)
[kW]
[A]
1
0.25
1.4
0.37
2.0
0.55
2.7
0.75
3.2
1.10
4.6
0.25
1.4
0.37
2.0
0.55
2.7
0.75
3.2
1.10
4.6
1.50
6.3
2.20
8.7
0.25
1.4
0.37
2.0
0.55
2.7
0.75
3.2
1.10
4.6
1.50
6.3
2.20
8.7
0.37
1.1
0.55
1.5
0.75
1.9
1.10
2.6
1.50
3.6
2.20
5.0
3.00
6.6
4.00
8.5
5.50
11.3
7.50
(15.2)
3
4
P (230V, 60 Hz)
[hp]
[A]
1
1/3
1.5
2
2
1/2
2.2
3/4
2.2
1
3.2
1-1/2
4.2
1/3
1.5
2
2
1/2
2.2
3/4
2.2
1
3.2
1-1/2
4.2
2
6.8
3
9.6
1/3
1.5
2
2
1/2
2.2
3/4
2.2
1
3.2
1-1/2
4.2
2
6.8
3
9.6
1/2
1.1
3/4
1.6
1
2.1
1-1/2
3
2
3.4
3
4.8
4
7.6
5.5
7.6
7-1/2
11
10
14
3
Installation
Size
FS2
FS2
FS2
FS2
FS3
FS1
FS1
FS1
FS2
FS2
FS2
FS3
FS1
FS1
FS1
FS2
FS2
FS2
FS3
FS1
FS1
FS1
FS2
FS2
FS2
FS3
FS3
FS3
FS3

Advertisement

loading