SETUP-functions
The SETUP is entered by pressing the setup-button for 10 seconds.
10 s.
Adjustable parameter
Post gas time
Pre gas time
Hot Start level
2T Hot Start duration
Crater fill end level
Crater fill time (angle)
Creep start starting level
Creep start time (angle)
Doublepulse freq.
Double pulse Wf-speed amplitude
Ignition pulse
Pulse top current
Post current time
Arc length adj. range
Calibration
Maximum wf-speed
Liquid cooled gun PTC
Gun controller automatic detection
Display recovery delay
Factory settings recall

Error codes

Net overvoltage
Err 3
Err 4
Power source overheated
Err 5
Cooling unit has stopped welding
Power source output voltage is has risen > 80 Vdc
Err 6
PMT-gun overheated or RMT 10 installed and PMT-gun in FU-position. In some cases this error may
Err 153
be presented if one of the main supply voltage phases are missing.
Err 154
Wf-motor overload (current > 4,5 A/ 5 s.)
Err 253
Wrong welding process
Parameter selection
Number
Display
1
2
11
12
14
15
17
18
21
22
31
33
35
41
42
51
53
54
81
99
Parameter adjustment
Factory setting
PoG
Syn
PrG
Syn
Hot
30
H2t
2.0
CFL
30
CFS
1
CSL
Syn
CSS
0
dFr
Syn
DA
Syn
StP
0
PuC
0
PoC
Syn
ALr
0
CAl
0
FS
18
Gun
On
GrE
On
dIS
5.0
FAC
OFF
Adj. range
Quantity
0.0...9.9
s
0.0...9.9
s
-50...+75
%
0.1...9.9
s
10...90
%
1...20
s/10m/min
10...90
%
0.1...5
s/10m/min
0.0...8.0
Hz
0.0...3.0
m/min
-9...0...+9
-10...+15
%
0.0...10
s
-50...+75
%
1.0
V/100A
18 tai 25
m/min
On/Off
On/Off
1.0...20
s
Off/Pan/All
6

Hide quick links:

Advertisement

Table of Contents
loading