General
The machine may be repaired only by an authorized and licensed technician or workshop!
First do a visual check to find the possible loose connectors, broken wires or signs of overheating
Troubleshooting diagram
PROBLEM
Power source doesn´t start
Power source can´t provide full
power.
POSSIBLE CAUSE
Net fuses or supply cable.
Net fuses or supply cable.
Main transformer T001 or
secondary siode card Z002.
REMEDY
Check the net fuses and supply cable
condition.
Check the net fuses and supply cable
condition.
Check the main transformer T001´s
ferrites and secondary diode card
diodes.
9