GENERAL INFORMATION
cord.
5. Do not pull or carry by cord. Do not close a door on cord or pull cord
around sharp edges or corners.
6. Do not run appliance over cord. Keep cord away from heated surfaces.
7. Do not use with damaged cord or plug. If cord is damaged, repair
immediately.
8. Do not use outdoors or on wet surfaces and or standing water.
9. Always unplug or disconnect the appliance from power supply when
not in use.
10. Do not allow to be used as a toy. Close attention is necessary when
used by or near children.
11. Do not use in areas where flammable or combustible material may
be present.
12. Do not leave the unit exposed to harsh weather elements. Tempera-
tures below freezing may damage components and void warranty.
13. Use only the appropriate handles to move and lift unit. Do not use any
other parts of this machine for this purpose.
14. Keep hair, loose clothing, fingers, and all parts of the body away from
all openings and moving parts.
15. Use extra care when using on stairs.
16. To reduce the risk of fire or electric shock, do not use this machine with
a solid-state speed control device.
17. The voltage and frequency indicated on the name plate must corre-
spond to the wall receptacle supply voltage.
18. When cleaning and servicing the machine, local or national regulations
may apply to the safe disposal of liquids which may contain: chemicals,
grease, oil, acid, alkalines, or other dangerous liquids.
19. Do not leave operating unattended.
Preparation
1. Remove furniture and other items from the area you are going to clean.
2. Vacuum carpet and upholstery, and remove debris.
3. Protect cabinets, walls and painted surfaces with drop cloths or plastic.
4. Inspect power cords for damages.

Operating Instructions

1. Fill the solution tank.
2. Attach female end of a solution hose to a wand or other tool and the
male end to the LTD's Quick Disconnect (QD).
3. Attach one end of a vacuum hose to a wand or other tool and the other
end to the LTD's 2" Cuff-Lynx vacuum hose ports.
4. Plug in power cords:
LTD3/5/12 Model: Using two separate circuits/breakers, plug in the
grounded power cables as previously instructed using the appropriate
grounding techniques.
The LED light strip will illuminate and sound a tone when plugged into
separate circuits/breakers.
2. When the hoses are attached, turn on Pump-Out switch.
3. The Prime Valve and Pressure Regulator are located on the front right
side of the solution tank and should be primed prior to use. To prime the
pump turn the valve to the Prime position for 30 seconds, and then turn
horizontally to the Run position.
4. Pull your wand's trigger to ensure water is running through the lines to
avoid damage to the Pump and Heating unit (LTD3).
5. (LTD3) The heater switch has three positions: Off (Middle); 1,000 watts
using 1 heater (Top); 600 watts & 1,600 watts using 2 heaters (Bottom)
If the water heater is to be used, prime system and turn it on to the desired
wattage and wait five minutes for the water to reach temperature.
6. To clean, make two dry passes for every one wet pass while work-
ing away from the power cords. For optimal use or heavily soiled areas,
repeat wash steps in the opposite direction.
7. To prevent motor or internal damage, use a preferred foam control
solution in the recovery tank. Remember to check for build-up in both the
recovery and solution tanks! When using auto-fill, make sure the pump-out
is ON while in-use.
8. Empty the Recovery Tank whenever you need to refill solution. Attach
the 45º drain elbow to the drain spout located in the back and lift the dump
valve to empty the tank.
9. Squeeze the wand or tool's trigger for five seconds after turning the
power switches off to relieve any existing line pressure.
10. When the machine is off: unplug the power cables, remove solution
and vacuum hoses, and empty the recovery tank by attaching the 45º
drain elbow.
11. To empty the solution tank, twist off the solution tank drain cap located
on the back of the machine.

After Use

1. Before storing the machine, drain, rinse and dry both the tanks and
vacuum hoses of any residual water or solution.
2. Store standing upright in a dry, enclosed location.
3. Leave the recovery tank lid open for better air circulation.
4. If storing in freezing temperatures, take extra precautions to make sure
the machine and solution systems are completely drained and dry.

Maintenance Schedule

Latches are located in the back to open the tank for internal maintenance.
To keep machine in good working condition, follow the below recom-
mended daily and weekly maintenance procedures. Relief valves should
be replaced annually.
Maintenance item
Clean and inspect tanks.
Clean and inspect hoses.
Check and clean internal filters by twisting
off, rinsing with clean water and replacing.
Check power supply cable.
Clean machine with all-purpose cleaner
and cloth.
Check spray nozzles.
Flush solution system with Mytee
Maintainer.
Remove and float shut-off screen from
tank and clean. Simply pull off.
Inspect vacuum hoses for holes and loose
cuffs.
Inspect spray pattern for clogging. If
clogged, remove spray tips and soak them
in a recommended liquid neutralizer for
up to six hours. To remove spray tip, twist
spray tip body counter-clockwise.
Lubricate wheels with water resistant oil.
Inspect machine for water leaks and loose
hardware.
Filter Maintenance
All LTD models have filters that need to be checked and cleaned after
each week of use. Regular filter maintenance is a simple way to extend
the life of your machines.
Pump-Out Filters
The pump-out filter is located on the inside bottom of the black vacuum
tank. It is recognizable by its cylindrical shape. To maintain filter:
1. Remove the 7" clear vacuum tank lid.
2. Reach in and remove the nylon mesh pre-filter that covers the main
cylindrical filter. Grasp the mesh, and pull straight up, easing the metal
ring upward, clearing the main filter. A flashlight may be needed to locate
the filter assembly.
3. Reach in and unthread the cylindrical filter by rotating it counter clock-
wise.
3. Once the filters are out, check for debris and damage. Rinse both the
pre-filter and the main filter of any debris or replace if damaged.
4. Place main filter back into vacuum tank by rotating it clockwise onto the
brass nipple.
5. Slide the ring on the pre-filter over the main filter, and push the ring to
the bottom of the tank, so that the entire mesh bag covers the main filter
screen.
Pump Filters
The pump is a half-circle shaped screen located on the inside bottom of
the blue solution tank. To maintain filter:
1. Open black solution tank lid.
3
Daily
Once a week
x
x
x
x
x
x
System
x
®
x
x
x
x
x

Advertisement