Operation; Troubleshooting; Machine Specifications; After Use - Mytee Flood Hog 7000SX Instructions Manual

Table of Contents

Advertisement

GENERAL INFORMATION
Pre-Operation
1. Remove furniture and other items from the area you are going to treat.
2. Make sure debris filter is clear and electrical cord is in good repair.
3. Make sure a 20A grounded wall outlet is available for cord. Do not use
extension cord.

Operation

1. Attach one end of the vacuum hose to the front of the machine. Then, attach a
scalloped or squeegee vacuum head to the other end of the vacuum hose.
2. If using the Auto Pump-Out feature: On the rear of the machine, attach the pump-
out hose. Secure the hose to the fitting using the cam lock. Push the hose cuff onto
the fitting, making sure the silver ears and rings are extended forward. Pull the ears
down using the rings until connection is tight. Place the end of the hose in a location
where dirty water can drain.
3. Plug in the power cord(s). Two power cords are located in the back of the ma-
chine. To power Vacuum 1 and Pump, plug in the top cord. To power the Vacuum
2, plug in the bottom cord. Plug each of the two power cords into two separate, 20A
grounded wall outlets. Do not use extension cords.
4. Turn on the machine. Three switches are located on the lower left side of the
machine. To use Vacuum 1, turn on the Vacuum 1 switch. To use Vacuum 2, turn on
the Vacuum 2 switch. To use the pump, turn on the Pump switch.
5. Place wand over flooded area and begin extracting.
6. If pump must be accessed during extraction, use the recovery tank lid on top of
the machine. Pull the lever up and turn counter clockwise until it faces the side of the
machine. Pull up and take the lid off. Use reverse procedure to replace.
7. When flood extraction is finished, turn off the machine.

After Use

1. Unplug power cords and remove hose.
2. Inspect hoses and replace if damaged.
3. Inspect filter and clean.
4. The debris filter inside the machine protects the vacuum motor from damaging
debris. Keep it clean by removing vacuum hose and turning the top latch counter-
clockwise and opening the lid. Remove stainless steel basket and gently rinse with
water. Dry with a soft cloth. Replace basket, lid and hose.
5. Flush out recovery tank and pump-out to prevent silt buildup around the
pump-out intake.
6. Open recovery tank to promote air circulation.
7. Make sure machine and hoses are completely drained and dry.
8. Store the machine in a clean, dry place.

Maintenance Schedule

Maintenance item
Clean and inspect Tanks
Clean and inspect Hoses
Flush out recovery tank and pump-out to prevent sift
buildup around the pump-out intake.
Inspect filters
Check electrical cord
Clean machine with all purpose cleaner and cloth
Inspect vacuum hoses for holes and loose cuffs
Lubricate wheels with water-resistant oil
Inspect machine for water leaks and loose hardware

Troubleshooting

There is no power.
1. Plug machine in proper outlet.
2. Check circuit breaker; reset circuit breaker, other items should not run on the
same circuit as machine. Outlet must be a 20 amp circuit. For 7000SX models, two
separate 20 amp circuits are required.
Pump-out does not work properly.
1. Check pump-out wire. May need to reconnect wire.
2. Switch plate switch may need to be replaced.
3. If pump motor brushes are worn, replace pump.
4. Float switch obstructed. Clean.
5. Pump-out intake is obstructed. Flush out recovery tank and pump-out to clear
pump-out intake.
Vacuum motor does not work properly.
1. Check that hose is tightly connected.
2. Close drain hose valve completely.
3. Secure the vacuum tank tightly.
4. If water is coming out of vacuum motor, use a low foaming detergent.
New & Reconditioned Equipment & Parts - www.southeasternequipment.net

Machine Specifications

Recovery Tank
Consumption
Machine Weight
230V Configuration Information
Model Number
Consumption
FAQs
Q: What comes standard with the 7000SX?
A: The 7000SX comes with a 2" x 1.5" Cuff Lynx™ (H141), a 50' lay-flat pump-out
hose (AH121), and pack of filters (G008).
Q: Where do I plug the machine in?
A: Plug each power cord into a separate, 20A grounded wall outlet. Outlets must
be on two separate breakers. When the amber light on the switch plate illuminates,
the machine is on separate circuits (not necessarily 20A circuits). You can identify the
primary cord by the yellow tag.
Q: Is there anything I can do to increase the expected life of my machine?
A: Running the vacuum motors with the tank empty and lid off will allow excess
moisture in the vacuums to dry off.
Daily
Once a week
x
x
x
x
x
x
x
x
x
3
Vacuum
Dual 3-stage high performance, in series
CFM
Water Lift
Pump-Out
Filter
Stainless steel strainer basket
Power
Cord 1: 18 amps @ 115V 60Hz
Cord 2: 13 amps @ 115V 60Hz
Machine
Dimensions
Power Cord
Power
Cord 1: 10 amps @ 230V 60Hz/50Hz
Cord 2: 7 amps @ 230V 60Hz/50Hz
12 gallons
113
249"
66 GPM
124 lbs.
29" x 17.5" x 35"
Dual 50' 12/3