Category 2 Dimensions - Full Bay Configuration - DaVinci Category 2 Owner's Manual

Custom fireplaces
Table of Contents

Advertisement

10
Category 2 Dimensions – Full Bay Configuration
12" Glass
42.625" (1083mm)
20" Glass
18.125"
50.625" (1286mm)
(461mm)
30" Glass
60.625"
(1540mm)
12" (305mm)
20" (508mm)
30" (762mm)
36" Glass
36" (915mm)
58" (1474mm)
66.625 (1693mm)
58" Glass
88.625" (2252mm)
12.5"
318mm
(a) Air intake – See table below for quantity - Location determined by fireplace length (see "Air Intake Duct Location" on page 69).
(b) Vent Collar – Uses 10" or 8" Diameter B-Vent (determined by power vent type). Centered on module.
(c) Gas Control Valve – Located to the front of the master module (front of fireplace is determined by gas control valve location).
(d) Electrical Junction Box – On master module (location determined at time of order – can be relocated), includes 120v input,
exhaust vent power/harness, on-off LED harness.
(e) Gas Inlet – On master module (NOTE: gas inlet is always located along the front edge, even if master module is to the left).
(f) Vent Collar Distance to Front/Back – Approx. 4.375" (112mm) for 10" B-Vent, 5.375" (137mm) for 8" B-Vent
Horizontal Dimensions & Specifications
Version
Width (x)
84" Full Bay
84" (2134mm)
96" Full Bay
96" (2439mm)
108" Full Bay
108" (2744mm)
120" Full Bay
120" (3048mm)
132" Full Bay
132" (3353mm)
© Travis Industries
Features and Specifications
Secondary
Module
Version
Length
Vent Loc. (y)
24" (610mm)
30" (762mm)
30" (762mm)
36" (915mm)
36" (915mm)
10/10/18 - 1418
a
f
Master
Module
c
x
Air Intakes
Power Vent
2
Low Volume
3
High Volume
3
High Volume
4
High Volume
4
High Volume
a
y
b
5.75"
(147mm)
d
e
19.75"
502mm
BTUs
Min. Weight
87,000
1100 lbs. 490Kg
101,500
1200 lbs. 534 Kg
116,000
1350 lbs. 601 Kg
130,500
1800 lbs. 802 Kg
145,000
2000 lbs. 891 Kg
DaVinci-Cat2+

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: