DaVinci Category 2 Owner's Manual page 84

Custom fireplaces
Table of Contents

Advertisement

84
Interior Power Vent - Minimum Vent Pre and Post Blower
Minimum Vent Pre-Blower = 2' Straight Section (24") – 4' (48") or more recommended)
Minimum Vent Post-Blower = 2' Straight Section (24") – 4' (48") or more recommended)
Interior Power Vent – Mounting
!
THE B-VENT AFTER THE EXHAUST BLOWER MUST BE SEALED
(use rtv silicone, pressure pipe, or equivalent). Certain jurisdictions
may require sealed b-vent pressure pipe (consult with your local
building official for requirements in your area).
!
The blower may be placed on its side or with the motor upwards. DO NOT
POSITION THE ASSEMBLY SO THE BLOWER MOTOR IS BELOW THE
ASSEMBLY – SEE ILLUSTRATION TO THE RIGHT. This will greatly
shorten blower life and void the warranty.
Use the included brackets to help secure the blower and exhaust damper in
place (see illustration below).
Use straps/supports/framing to secure the blower in a workmanlike manner.
Test the blower prior to sealing the vent enclosure to ensure proper noise abatement has been
achieved. You way wish to isolate the blower mounting to reduce vibration.
© Travis Industries
Installation
6/19/18 - 1418
(for qualified installers only)