10
Dimensions – Full Bay Configuration
12" Glass
41.125" (1045mm)
20" Glass
49.125" (1286mm)
12" (305mm)
30" Glass
20" (508mm)
59.125" (1502mm)
30" (762mm)
36" (915mm)
36" Glass
65.125 (1655mm)
280mm
(a) Air Intake - 6" Diameter, Centered on Fireplace, Left or Right Side (determined at time of order)
(b) Exhaust - 10" or 8" Diameter B-Vent (determined by exhaust blower type), Centered on Fireplace
(c) Gas Inlet – Location is determined at time of order (can be relocated)
(d) Electrical Junction Box – On both sides (location determined at time of order – can be relocated), includes
120v input, exhaust vent power/harness, on-off LED harness
(e) Gas Control Valve

Horizontal Dimensions

Version
48" Full Bay
60" Full Bay
72" Full Bay
© Travis Industries
Features and Specifications
d
11"
c
e
Overall Width (x)
48.125" (1223mm)
60.125" (1528mm)
72.125" (1832mm)
16.375"
416mm
a
b
Version
Length
x
Exhaust Location (y)
24" (610mm)
30" (762mm)
36" (915mm)
4140805
y
16.375"
416mm
a
(147mm)
d
c
20"
508mm
BTUs
43,500
58,000
72,500
100-01384
5.75"