Tightening the Titan Lock Connectors

With the glass opening height aligned, the Titan Locks may now be fully tightened. Start with the upper
outer braces. Tighten these braces to approximately 80 ft/lbs (very tight). The upper inner brackets may
then be tightened snug (approximately 20 ft/lbs). Next tighten the lower outer braces (approximately 80
ft/lbs). Lastly, tighten the inner lower brackets snug (20 ft/lbs.).
7/8" Socket Wrench (outer braces)
NOTE: After tightening the Titan Locks, double-check the glass opening height. It should be uniform
across the width of the glass opening. If it is not, you will need to loosen the titan locks, adjust the
alignment tool, then re-tighten the titan locks.

Remove the Installation Alignment Tool(s)

Loosen the wing nuts on the alignment tool(s) and remove them from the fireplace. The alignment tools
may be recycled after fireplace installation is complete.
© Travis Industries
Installation
6/19/18 - 1418
(for qualified installers only)
7/16" Socket Wrench (inner braces)