Accessing Internal Components

Most internal components can be accessed by removing the front glass pane and intake air channel
media tray (see instructions below). If more extensive access is required, see "burner removal" on the
following page.
-- Turn off gas to the fireplace prior to accessing internal components to prevent accidental ignition.
-- Shut off electricity to the fireplace to protect internal circuits.
Remove the front outer glass pane (see page 93). Remove the intake air channel media tray.
At this point most of the internal components may be accessed (see descriptions below).
Burner Air Shutter
Rheostat
Internal Shut Off Valve Access
The internal shutoff is accessed following the directions above. The valve is positioned near the gas inlet
(left, right, or bottom).
NOTE: The shut off valve must be closed while pressure testing the gas line leading to the fireplace.
© Travis Industries
Installation
LED Controller
- May be placed on its side
- May be on right side
LEFT SIDE
CENTER
(for qualified installers only)
Air Pressure
Switch
Fireplace Controller
6/19/18 - 1418
Shutoff Valve
- May be on left side
RIGHT SIDE
Gas Control Valve
Power Vent Controller
49