C h a r g e r D a m p e r ™ R C S e r v i c e - Y a r i ™
2 0 0 H o u r S e r v i c e
Turn the compression adjuster knob counter-clockwise, to the full open
1
position, until it stops.
Remove the retaining screw and remove the knob (RC).
2
Unthread the damper top cap and remove the damper assembly.
3
Clean the upper tube threads.