4. Verify proper fuse value (1.0 A, 250 V, slow blow).
5. Reinstall the fuse (or replacement fuse) and the fuse-
holder cap.

INSTRUMENT COOLING

Always maintain adequate instrument cooling. The venti­
lation holes on both sides of the instrument cabinet and on
the rear panel must remain free of obstruction.

CONTROLS, CONNECTORS, AND INDICATORS

The following descriptions are intended to familiarize the
operator with the location, operation, and function of the
instrument's controls, connectors, and indicators.
DISPLAY, POWER, AND PROBE ADJUST
Refer to Figure 2-3 for location of items 1 through 8.
f 1 ) Internal Graticule— Eliminates parallax viewing error
between the trace and graticule lines. Rise-time ampli­
tude and measurement points are indicated at the left
edge of the graticule.
2 j
f
POWER Switch— Turns instrument power on and off.
Press in for ON; press again for OFF.
f 3^ Power Indicator— An LED that illuminates when the
^
'
instrument is operating.
(4
j FOCUS
Control— Adjusts
^ ~ ' definition.
2-2
M j)P R O B E ADJUST Connector— Provides an approxi-
^
( 6 J BEAM FIND Switch— When held in, compresses the
^ 8 ^ A and B INTENSITY Controls— Determines the
for
optimum
display
'
C A U T IO N
FOR C0NTIRUE0 FIRE PROTECTION
REPLACE ONLY W IT H SPECIFlEO
TYPE ANO RATED FUSE
DISCONNECT
POWER INPUT BEFORE REPLACING FUSE
FUSE 250V
LINE VOLTAGE RANGE
1A SLOW
9 0 250VAC
0 0 NOT REMOVE
COVER REFER
SERVICING TO
0UALIFIE0
PERSONNEL
POWER
M AX WATTS 4 0
M AX VA 70
FREQ 4 8
4 4 0 to
TEKTRONIX. INC . BEAVERTON. OREGON. U S A
POWER
CORD
Figure 2-2. Fuse holder and power cord connector.
mately 0.5 V, negative-going, square-wave voltage (at
approximately 1 kHz) that permits an operator to
compensate voltage probes and to check operation of
the oscilloscope vertical system. It is not intended for
verifying the accuracy of the vertical gain or time-base
circuitry.
y display to within the graticule area and provides a visi­
ble viewing intensity to aid in locating off-screen
displays.
TRACE ROTATION Control— Screwdriver adjust­
ment used to align the crt trace with the horizontal
graticule lines.
'
brightness of the A and B Sweep traces.
C A U T IO N
TO AVOIO ELECTRIC
SHOCK. THE POWER
CORO PROTECTIVE
GROUNOING CONDUCTOR
/
MUST BE CONNECTED
1 TO GROUNO
EXT Z AXIS INPUT
I0 K Q
POSITIVE GOING
INPUT OECREASES
INTENSITY
S VOLT P P CAUSES
NOTICEABLE
MODULATION AT
NORMAL INTENSITY
5 3 0 V PEAK
u