EPLACING
H
EATER
E
LEMENTS
Continued
6-28
T
ROUBLESHOOTING
WARNING:
hot surface hazards
Before attempting maintenance of any kind
on the Thermolator, you must stop the unit;
disconnect and lockout the main power
supply; and allow the unit to cool to less than
100°F (38°C)
1
Disconnect and lockout the main power.
2
Remove the top panel of the Thermolator.
3
Remove the heater cap.
Use a 1/4-inch open-end
wrench to remove the three
bolts that hold the cap to the
heater tank.
4
Remove the heater
wiring harness. Label the
wiring layout of the heater ter-
minals; wires are labeled 2T1,
2T2, 2T3 and GND.
Thermolator TW Series
Electrical shock and
Heater
cap