Control Logging Operating Hours; Operating Hours - Conair Thermolator TW-1 User Manual

Water temperature control units
Table of Contents

Advertisement

TW-1, TW-2
C
ONTROL
L
OGGING
O
PERATING
H
OURS
5-12
M
AINTENANCE
You can see the total numbers of operation by accessing the
Total Operating Hours Log in Test Mode.
1
Enable Test Mode.
2
Press any key to display the first test menus.
3
Index through test menus to the operating log.
Press and hold the Setpoint
index to each test menu until the Actual display indicates
"Log". The Setpoint display indicates the total number of
operating hours in 100-hour units.
4
Exit the Operating Hours Log.
Press and hold the Select
and index to the next test.
You can now proceed to another menu in Test Mode, or dis-
able Test Mode and resume normal operation.
TO DISABLE TEST MODE, complete steps 2 through 5
in "Performing System Tests, Section 5" setting dip
switch 6 to OFF instead of ON.
Thermolator TW Series
key for 3 seconds to
key for 3 seconds to exit
UGH025-0504