Conair Thermolator TW-1 User Manual page 32

Water temperature control units
Table of Contents

Advertisement

TW-2 C
ONTROL
S
ELECTING THE
T
EMPERATURE
C
P
ONTROL
CONTINUED
3-16
I
NSTALLATION
OINT
8
Press the RUN button to save the control
point.
u
The control will display "Pr OFF" to prompt you to
remove power to the unit.
IMPORTANT: If RUN is not pressed, the new
control point source will not be saved.
9
Turn off power to the unit.
Disconnect and lock out the
main power supply.
10
Open the electrical
enclosure.
11
Set dip switch 5 to OFF.
12
Close the electrical enclosure and restore
power to the unit. The TW-2 will now control the process
temperature based on actual temperatures recorded at the
new control point source.
Thermolator TW Series
8 7 6 5 4 3 2 1
UGH025-0504