Disabling Passcode Protection - Conair Thermolator TW-1 User Manual

Water temperature control units
Table of Contents

Advertisement

TW-1, TW-2
C
ONTROL
E
NABLING AND
D
ISABLING
P
ASSCODE
P
ROTECTION
CONTINUED
3-14
I
NSTALLATION
7
Press the RUN button to save the passcode.
u
The control will display "Pr OFF" to prompt you to
remove power to the unit.
IMPORTANT: If RUN is not pressed, the new
passcode will not be saved.
8
Turn off power to the unit. Disconnect and
lock out the main power supply.
9
Open the electrical
enclosure.
10
Set dip switch 3 to
OFF.
11
Close the electrical enclosure and restore
power to the unit. A passcode now is required to change
system parameters.

Disabling Passcode Protection

To disable passcode
protection and allow
universal access to
system parameters:
1
Follow Steps 1
through 5 in the
previous section
on enabling pass-
code protection.
Hold down the t setpoint adjustment button
2
to select "OFF" as the new passcode.
3
Follow steps 7 through 11, above.
Thermolator TW Series
8 7 6 5 4 3 2 1
UGH025-0504

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thermolator tw-2Thermolator tw

Table of Contents