The TW Thermolator can be ordered with an optional purge
TW
valve, which clears the process lines of fluid using com-
pressed air. The valve is operated by an optional manual purge
URGE
button on the control panel
IMPORTANT:
that the cooling water source feed is closed. If the feed is
open and the air line has a higher pressure than the cooling
water, air may be injected into the cooling water system. If
the cooling water pressure is higher than the air line, cooling
water may be injected into the air line.
1
Press
2
Shut off the cooling water supply valve.
3
Press Both
Purge (PUr) to start purging.
u The Purge button lights.
u The Vent and Cool outputs are activated.
u The STOP and RUN buttons are deactivated during the
The time required to clear the process lines of fluid will
vary according to the length of the process piping and the
size of the tooling.
4
Press Both
Thermolator TW Series
Before purging the process lines, be sure
Stop/Start
purge or when the cool delay off timer is active.
to stop the Thermolator.
at once to toggle Mold
again to stop purging.
UGH025-0504