Verify that the
1
valve is in the
closed position.
The position of
the ball opening
is indicated by
the index on top
of the shaft.
2 Slide the actuator
straight down
over the valve
shaft and onto the
mounting plate,
with the "R" side
facing up. On
MS40-703 mod-
els, the rotation
switch must be in
the "R" position.
Align the actuator
3
with the mount-
ing plate, then
slide the anti-
rotation clip half
way into the slot
on the bottom of
the actuator.
UGH025-0504
Tighten the wing
4
nut to secure the
anti-rotation clip
in place. Be care-
ful not to over-
tighten the wing
nut.
Thermolator TW Series
Using a 10 mm
5
wrench or socket,
evenly tighten the
two nuts on the
shaft clamp,
applying 8 to 10
lb-ft (11 to 14 N-
m) of torque.