The table lists the limits and defaults for the pulse mode para-
meters.
Parameter
Pulse Cycle Time
Pulse Time
When the Pulse Cycle Time is set to Off the Pulse Mode is
disabled.
Whenever the process value is within the alarm band, the
alarm delay shall be canceled. The deviation alarm delay
timer only starts when out of dead band.
Follow these steps to access the deviation alarm
inhibition/delay parameters:
The table lists the limits and defaults for the Alarm
Inhibition/Alarm Delay parameters. The values are adjustable
in 0.5 minute increments.
Parameter
Alarm Delay Time
Deviation Band
Thermolator TW Series
Low Limit
High Limit
Off, 0.1 minute
15.0 minutes
0.5 seconds
5 seconds
High Limit
Low Limit
1800 seconds
1.0 second
1ºF
Default Value
Off
1 second
Default Value
600 seconds
45ºF
20ºF
UGH025-0504