Command Name
GET IN n1 EDID n2
GET IN EDID LIST nn
SET EDID n NAME s
GET EDID n NAME s EDID TABLE
19
Description
input EDID table
query
input EDID table list
query
EDID TABLE SELECT
SELECT
Description of parameter
n1 = 1,2,3,4... 8
n2 = 1,2,3... 22
(1-INT1, 2-INT2...,7-
USER1,8-USESR2...,15-
Sink A, 16-Sink B)
Total User EDID number
equal to Input source
number.
Total Sink EDID number
equal to output
number of device.
nn = 1,2,3...
22(1-INT1, 2-
INT2...,7-
USER1,8-
USESR2...,15-
Sink A, 16-Sink
B)
Total User EDID
number equal
to Input source
number.
Total Sink EDID
number equal
to output
number of
device.
n = 7,8,9,...14 (only USER
EDID name can be
edited)
s = string
name size : 32 Byte
n = 7,8,9,...14 (only USER
EDID name can be
edited)
s = string
name size : 32
Byte