OPERATION AND MAINTENANCE

Depth Stop Adjustment (Manual)

The operating depth of the VT Plus is controlled by a
single-point depth stop. The stop is located at the center
front of the machine.
1. Adjust the depth stop by turning the handle in
(clockwise) to increase operating depth (See
Figure 4-18.) Turn the handle out
(counter-clockwise) to decrease operating depth.
One turn will equal approximately 3/16" adjustment in
depth.
2. The gauge on the side of the depth stop tube gives a
reference for depth setting. The "A" setting refers to
maximum operating depth.
IMPORTANT
For maximum operating depth, the lift wheels must
be in contact with the ground and carry some of the
machine weight. Raising the lift wheels off the
ground, permits uncontrolled depth of each frame
section and does not allow the leveler to function
properly.
4-16
DEPTH STOP TUBE
DEPTH STOP
GAUGE
7431depthstopadj
Figure 4-18: Depth Stop Adjustment (Manual)
DEPTH STOP HANDLE
F-561-0818